How to Select Definite Purpose Contactor?

Choosing the right BYSON definite purpose contactor requires consideration of parameters, application requirements, safety standards, and brand-specific features. Below is a step-by-step guide to help you make the best selection.
What is a Definite Purpose Contactor:
A definite purpose contactor is an electrically operated switch designed for specific, high-volume applications — most commonly in HVAC (Heating, Ventilation, Air Conditioning) , refrigeration, and food service equipment.
Common Specifications:
| Parameters | Description | Values |
| Full Load Current Inductive (FLA) | Continuous current the contactor can carry while the motor runs normally. Contactor FLA must be ≥ motor FLA. | Residential AC: 25A, 30A, 40A Commercial equipment: up to 90A or higher |
| Locked Rotor Current (LRA) | Peak inrush current the contactor must handle when the motor starts (usually 5–6× FLA). Contactor LRA must be ≥ motor LRA. | In a 240V system, LRA is often 6 times the FLA. |
| Coil Voltage | Control voltage that energizes the contactor. | Common for residential use: 24VAC, 120VAC, 208/240VAC |
| Poles Number | How many circuits the contactor switches. | 1P, 2P (most common for residential AC), 3P, 4P |
How to Choose BYSON ATS:
| Model | Contactor Form Per Circuit | Full Load Current Inductive | Locked Rotor Current | Resistive Amps Rating | Nominal Coil Voltage | ||
| BS-1.5-20A | 1 Pole NO with Shunt | 20A | 120A@240VAC-277VAC | 100A@480VAC | 80A@600VAC | 30A | 24VAC 120VAC 208/240VAC 277VAC |
| BS-1.5-25A | 25A | 150A@240VAC-277VAC | 125A@480VAC | 100A@600VAC | 35A | ||
| BS-1.5-30A | 30A | 180A@240VAC-277VAC | 150A@480VAC | 120A@600VAC | 40A | ||
| BS-1.5-40A | 40A | 240A@240VAC-277VAC | 200A@480VAC | 160A@600VAC | 50A | ||
| BS-2P-20A | 2 Poles NO | 20A | 120A@240VAC-277VAC | 100A@480VAC | 80A@600VAC | 30A | |
| BS-2P-25A | 25A | 150A@240VAC-277VAC | 125A@480VAC | 100A@600VAC | 35A | ||
| BS-2P-30A | 30A | 180A@240VAC-277VAC | 150A@480VAC | 120A@600VAC | 40A | ||
| BS-2P-40A | 40A | 240A@240VAC-277VAC | 200A@480VAC | 160A@600VAC | 50A | ||
| BS-2P-50A | 50A | 300A@240VAC-277VAC | 250A@480VAC | 200A@600VAC | 60A | ||
| BS-2P-60A | 60A | 360A@240VAC-277VAC | 300A@480VAC | 240A@600VAC | 75A | ||
| BS-2P-75A | 75A | 450A@240VAC-277VAC | 375A@480VAC | 300A@600VAC | 90A | ||
| BS-2P-90A | 90A | 540A@240VAC-277VAC | 450A@480VAC | 360A@600VAC | 120A | ||
| BS-3P-20A | 3 Poles NO | 20A | 120A@240VAC-277VAC | 100A@480VAC | 80A@600VAC | 30A | |
| BS-3P-25A | 25A | 150A@240VAC-277VAC | 125A@480VAC | 100A@600VAC | 35A | ||
| BS-3P-30A | 30A | 180A@240VAC-277VAC | 150A@480VAC | 120A@600VAC | 40A | ||
| BS-3P-40A | 40A | 240A@240VAC-277VAC | 200A@480VAC | 160A@600VAC | 50A | ||
| BS-3P-50A | 50A | 300A@240VAC-277VAC | 250A@480VAC | 200A@600VAC | 60A | ||
| BS-3P-60A | 60A | 360A@240VAC-277VAC | 300A@480VAC | 240A@600VAC | 75A | ||
| BS-3P-75A | 75A | 450A@240VAC-277VAC | 375A@480VAC | 300A@600VAC | 90A | ||
| BS-3P-90A | 90A | 540A@240VAC-277VAC | 450A@480VAC | 360A@600VAC | 120A | ||
| BS-4P-25A | 4 Poles NO | 25A | 150A@240VAC-277VAC | 125A@480VAC | 100A@600VAC | 30A | |
| BS-4P-30A | 30A | 180A@240VAC-277VAC | 150A@480VAC | 120A@600VAC | 40A | ||
| BS-4P-40A | 40A | 240A@240VAC-277VAC | 200A@480VAC | 160A@600VAC | 50A | ||
Note:
A definite purpose contactor from one brand may look identical to another brand's model but have different LRA ratings. Always match by FLA, LRA, coil voltage, and poles number. When replacing a contactor, you cannot simply match its size or ampere rating to a different brand or type. DP contactors have lower locked rotor current limits compared to general-purpose contactors of the same FLA. To find a suitable replacement, always use the original manufacturer's part number. If that's not possible, base your selection strictly on the motor's FLA and LRA nameplate values.